cart(0)cart
       
Your Position: Home > DOCUMENTS & REFERENCE > MSDS > N-ALFA-FMOC-N-Y-BOC-L-2,4 DIAMINOBUTYRIC ACID

N-ALFA-FMOC-N-Y-BOC-L-2,4 DIAMINOBUTYRIC ACID

Material Safety Data Sheet
N-ALFA-FMOC-N-Y-BOC-L-2,4 DIAMINOBUTYRIC ACID

Section 1 - Chemical Product and Company Identification
MSDS Name: N-ALFA-FMOC-N-Y-BOC-L-2,4 DIAMINOBUTYRIC ACID  
Catalog Numbers: SC-10166
Identified uses : Laboratory chemicals, Manufacture of substances

Section 2 - Composition, Information on Ingredients 
CAS#125238-99-5
Chemical Name: N-ALFA-FMOC-N-Y-BOC-L-2,4 DIAMINOBUTYRIC ACID
Percent: 98%min
EINECS/ELINCS: Not available

Section 3 - Hazards Identification 
3.1 Classification of the substance or mixture
Not a hazardous substance or mixture.
3.2 GHS Label elements, including precautionary statements
Not a hazardous substance or mixture.
3.3 Hazards not otherwise classified (HNOC) or not covered by GHS - none  

Section 4 - First Aid Measures 
4.1 Description of first aid measures
If inhaled: If breathed in, move person into fresh air. If not breathing, give artificial respiration.
In case of skin contact: Wash off with soap and plenty of water. 
In case of eye contact: Flush eyes with water as a precaution.
If swallowed: Never give anything by mouth to an unconscious person. Rinse mouth with water.
4.2 Most important symptoms and effects, both acute and delayed
The most important known symptoms and effects are described in the labelling (see section 2.2) and/or in section 11
4.3 Indication of any immediate medical attention and special treatment needed
no data available

Section 5 - Fire Fighting Measures 
5.1 Extinguishing media
Suitable extinguishing media
Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.
5.2 Special hazards arising from the substance or mixture
Carbon oxides, nitrogen oxides (NOx)
5.3 Advice for firefighters
Wear self contained breathing apparatus for fire fighting if necessary.
5.4 Further information
no data available

Section 6 - Accidental Release Measures 
6.1 Personal precautions, protective equipment and emergency procedures
Avoid dust formation. Avoid breathing vapours, mist or gas.  For personal protection see section 8.
6.2 Environmental precautions
Do not let product enter drains.
6.3 Methods and materials for containment and cleaning up
Sweep up and shovel. Keep in suitable, closed containers for disposal.
6.4 Reference to other sections
For disposal see section 13.

Section 7 - Handling and Storage 
7.1 Precautions for safe handling
Provide appropriate exhaust ventilation at places where dust is formed.
For precautions see section 2.2.
7.2 Conditions for safe storage, including any incompatibilities
Keep container tightly closed in a dry and well-ventilated place.
Recommended storage temperature: 2 - 8 °C
Store under inert gas. Keep in a dry place.
7.3 Specific end use(s)
Apart from the uses mentioned in section 1.2 no other specific uses are stipulated

Section 8 - Exposure Controls, Personal Protection 
8.1 Control parameters
Components with workplace control parameters, Contains no substances with occupational exposure limit values.
8.2 Exposure controls
Appropriate engineering controls
General industrial hygiene practice.
Personal protective equipment
Eye/face protection
Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).
Skin protection
Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands.
 
Body Protection
Choose body protection in relation to its type, to the concentration and amount of dangerous substances, and to the specific work-place., The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace.
Respiratory protection
Respiratory protection is not required. Where protection from nuisance levels of dusts are desired, use type N95 (US) or type P1 (EN 143) dust masks. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).
Control of environmental exposure
Do not let product enter drains.

Section 9 - Physical and Chemical Properties 
Physical State: poweder
Color: white
Odor: Not available.
pH: Not available.
Vapor Pressure: Not available.
Viscosity: Not available.
Boiling Point: Not available.  
Freezing/Melting Point:Not available.
Autoignition Temperature: Not available.
Flash Point: Not available.
Decomposition Temperature: Not available.
Water Solubility: Not available.
Specific Gravity/Density:Not available.
Molecular Formula: C24H28N2O6
Molecular Weight: 440.49

Section 10 - Stability and Reactivity 
Chemical Stability: Stable under recommended storage conditions.
Conditions to Avoid: Not available.
Incompatibilities with Other Materials: Strong oxidizing agents.
Hazardous Decomposition Products: Other decomposition products - no data available
In the event of fire: see section 5

Section 11 - Toxicological Information 
Acute toxicity: no data available
Inhalation: no data available
Dermal: no data available
Skin corrosion/irritation: no data available
Serious eye damage/eye irritation: no data available
Respiratory or skin sensitisation: no data available
Germ cell mutagenicity: no data available
Carcinogenicity
IARC: No component of this product present at levels greater than or equal to 0.1% is identified as probable, possible or confirmed human carcinogen by IARC.
ACGIH: No component of this product present at levels greater than or equal to 0.1% is identified as a carcinogen or potential carcinogen by ACGIH.
NTP: No component of this product present at levels greater than or equal to 0.1% is identified as a known or anticipated carcinogen by NTP.
OSHA: No component of this product present at levels greater than or equal to 0.1% is identified as a carcinogen or potential carcinogen by OSHA.
Reproductive toxicity: no data available
Specific target organ toxicity - single exposure: no data available 
Specific target organ toxicity - repeated exposure: no data available
Aspiration hazard: no data available
Additional Information
RTECS: Not available

Section 12 - Ecological Information 
12.1 Toxicity: no data available
12.2 Persistence and degradability: no data available
12.3 Bioaccumulative potential: no data available
12.4 Mobility in soil: no data available
12.5 Results of PBT and vPvB assessment: PBT/vPvB assessment not available as chemical safety assessment not required/not conducted
12.6 Other adverse effects: no data available

Section 13 - Disposal Considerations 
13.1 Waste treatment methods
Product: Offer surplus and non-recyclable solutions to a licensed disposal company.
Contaminated packaging: Dispose of as unused product.

Section 14 - Transport Information 
DOT (US)           Not dangerous goods
IMDG              Not dangerous goods
IATA               Not dangerous goods

Section 15 - Regulatory Information 
SARA 302 Components
SARA 302: No chemicals in this material are subject to the reporting requirements of SARA Title III, Section 302.
SARA 313 Components
SARA 313: This material does not contain any chemical components with known CAS numbers that exceed the threshold (De Minimis) reporting levels established by SARA Title III, Section 313.
SARA 311/312 Hazards: No SARA Hazards

Section 16 - Additional Information
While the information herein is believed to be reliable, it is furnished without warranty of any kind. It shall be used only as a guide. We assume no liabilities from the use of this product or information contained herein.